Skip to main content

Battery Discharge Measurement Circuit Diagram


Battery-life measurement for a portable system is a time-consuming task and many methods used for it do not give reliable results. Presented here is a circuit using which you can measure the battery-life very easily. Here, an analogue clock tracks the discharge time of the battery used in battery-powered portable devices.

Circuit and working
The circuit for battery-discharge measurement is shown in Fig. 1. It is built using low-power single-/dual-supply comparator MAX921 (IC1), MOSFET VN0300L (IRF1), an analogue clock and a few other components.

IC1 monitors the life of the BUT (battery under test) and controls the power supply for the analogue clock. When the BUT voltage falls below the threshold value set by VR1, IC1’s output becomes low, which turns off MOSFET IRF1. This means, power supply for the analogue clock is cut off and so the clock stops running. The reading on the clock at this point gives the discharge time of the BUT, provided you had set the clock to 12:00 before testing started. The circuit can test 2.5V to 11V batteries.


Fig. 1: Circuit diagram for battery-discharge measurement



Fig. 2: An actual-size PCB pattern for the circuit


Fig. 3: Component layout for the PCB

Construction and testing
 An actual-size, single-side PCB for the circuit is shown in Fig. 2 and its component layout in Fig. 3. After assembling the circuit on PCB, enclose it in a suitable plastic box. Connect positive terminal of the analogue clock to positive terminal of a 1.5V AA-size battery and negative terminal to the drain of MOSFET IRF1. Before using the circuit, verify that voltages at the test points are as per table.




For setting the threshold voltage, you need a variable DC power supply at CON1. For example, to measure the discharge time of a 6V battery (BUT), first decide its minimum threshold voltage, say 4.5V. Connect variable supply to CON1 and set it to 4.5V. Vary VR1 till the clock stops running. Now, remove the variable power supply, set the clock to 12:00 and connect the 6V battery at CON1. Connect the load across the battery. As the battery power is being consumed by the load, voltage level begins to drop. When BUT voltage drops below 4.5V, the clock stops running. The time shown on the analogue clock at this point is the discharge time.




Sourced By: EFY: Author : Bhaskar Pandey

Comments

Popular posts from this blog

OP AMP INTEGRATOR CALCULATOR

Enter the Input Voltage,Vin: Volts Enter the Frequency, f: Hertz Enter the Input Resistance, Rin: Ohms Enter the Value of Capacitor, C: Farads Output Voltage, Vout: Volts OP AMP based Integrator Tutorial and Design

Using the TLP250 Isolated MOSFET Driver Explanation and Example Circuits

I’ve already shown how to drive an N-channel MOSFET (or even an IGBT) in both high-side and low-side configurations in a multitude of ways. I’ve also explained the principles of driving the MOSFETs in these configurations. The dedicated drivers I’ve shown so far are the TC427 and IR2110. Some people have requested me to write up on MOSFET drive using the very popular TLP250. And I’ll explain that here. The TLP250, like any driver, has an input stage, an output stage and a power supply connection. What’s special about the TLP250 is that the TLP250 is an optically isolated driver, meaning that the input and output are “optically isolated”. The isolation is optical – the input stage is an LED and the receiving output stage is light sensitive (think “photodetector”). Before delving any further, let’s look at the pin configuration and the truth table. Fig. 1 - TLP250 Pin Configuration Fig. 2 - TLP250 Truth Table Fig. 1 clearly shows the input LED side and the receiving photodetector as well

MICROLAB A6331 – MICROLAB A6612 – HTS Circuit Diagram 4558 – TDA7377 – TC4053 – TDA2030A

Schematic: Microlab A6612 and Microlab A6331 Home Theater system .  Used ICs:  4558 – TDA7377 – TC4053 – TDA2030A A6331 - Circuit Diagram A6612 Circuit Diagram Click on the schematics to magnify