Networking between E1000 terminals using BDTP Technology. 1. Material Requirement The required material for the setup is as follows Sr. no. Material 1 PLC Type : FX Series 2 CPU : FX2N 3 PLC S/W : GX Developer Ver. 8.45X 4 HMI : E1041,E1043 5 Other 2. Diagram Network communication via BDTP is used to connect two or more E1000 -series operator terminals to one or two controllers or several operator terminals to two or more controllers, with retained performance. Figure 1 Networking between E –Terminals using BDTP Technology Cables The required cables are as follows Sr. no. Item Description 1 Medoc cable Prog. cable for FX PLC 2 Ethernet Cross Cable Comm. Cable for E-Terminal to E-Terminal & PLC*1 *1 To connect the E-Ter...