Skip to main content

Automatic AC Power Switch


for the Holiday Home

Electrical appliances accidentally left on  in (holiday) homes left unoccupied for a  short or a long period consume power  unnecessarily and can present a fire hazard. Everyone will be familiar with those  nagging thoughts, a few miles down the  road from the house: “Did I remember  to switch off the coffee machine? The  lights? The oven?”

Circuit diagram :

Automatic AC Power Switch-Circuit Diagram

Automatic AC Power Switch Circuit Diagram

Hotel rooms are often equipped with a  switch near the main door which enables the power supply to everything in  the room only when the plastic card (which  might contain a chip or have a magnetic strip  or a pattern of holes) that serves as the room  key is inserted. The circuit idea given here  to switch off lights and other appliances is  along the same lines. The solution is surprisingly simple.

A reed contact is fitted to the frame of the main entrance door, and a matching magnet  is attached to the door itself such that when  the door is closed the reed contact is also  closed. To enable power to the house, press  S1 briefly. Relay RE1 will pull in and complete  the circuit for all the AC powered appliances in  the house. The relay will be held in even after  the button is released via the second relay contact and the reed contact (‘latching’ function).

As soon as the main entrance door is  opened, the reed contact will also open.  This in turn releases the latch circuit and  consequently the relay drops out. The  various connected appliances will thus  automatically and inevitably be switched  off as soon as the house is left. The circuit is principally designed for  small holiday homes, where this mode  of operation is particularly practical. Of course, for any circuit that deals in AC  powerline voltages, we must mention  the following caution.

Caution:

shock hazard! Construction and connection of this circuit  should only be carried out by suitably-qualified  personnel, and all applicable electrical safety  regulations must be observed. In particular, it  is essential to ensure that the relay chosen is  appropriate for use at domestic AC grid volt-ages and is suitably rated to carry the required  current.

Author : Stefan Hoffmann – Copyright : Elektor


Comments

Popular posts from this blog

OP AMP INTEGRATOR CALCULATOR

Enter the Input Voltage,Vin: Volts Enter the Frequency, f: Hertz Enter the Input Resistance, Rin: Ohms Enter the Value of Capacitor, C: Farads Output Voltage, Vout: Volts OP AMP based Integrator Tutorial and Design

Block diagram of AM transmitter and receiver with explanation

Block diagram of AM transmitter and receiver with explanation AM Transmitter : Transmitters that transmit AM signals are known as AM transmitters. These transmitters are used in medium wave (MW) and short wave (SW) frequency bands for AM broadcast. The MW band has frequencies between 550 KHz and 1650 KHz, and the SW band has frequencies ranging from 3 MHz to 30 MHz. The two types of AM transmitters that are used based on their transmitting powers are: ·          High Level ·          Low Level High level transmitters use high level modulation, and low level transmitters use low level modulation. The choice between the two modulation schemes depends on the transmitting power of the AM transmitter. In broadcast transmitters, where the transmitting power may be of the order of kilowatts, high level modulation is employed. In low power transmitters, where only a few watts of transmitting power are required , low...

Using the TLP250 Isolated MOSFET Driver Explanation and Example Circuits

I’ve already shown how to drive an N-channel MOSFET (or even an IGBT) in both high-side and low-side configurations in a multitude of ways. I’ve also explained the principles of driving the MOSFETs in these configurations. The dedicated drivers I’ve shown so far are the TC427 and IR2110. Some people have requested me to write up on MOSFET drive using the very popular TLP250. And I’ll explain that here. The TLP250, like any driver, has an input stage, an output stage and a power supply connection. What’s special about the TLP250 is that the TLP250 is an optically isolated driver, meaning that the input and output are “optically isolated”. The isolation is optical – the input stage is an LED and the receiving output stage is light sensitive (think “photodetector”). Before delving any further, let’s look at the pin configuration and the truth table. Fig. 1 - TLP250 Pin Configuration Fig. 2 - TLP250 Truth Table Fig. 1 clearly shows the input LED side and the receiving photodetector as well...